Model NO. | TL-40W-L |
Certification | CCC, CE, C-tick, EMC, ETL, FCC, LVD, REACH, RoHS, SAA |
Voltage | 90-260V |
Beaming Angle | 25, 60 , 90, 120 Degrees,Asymmetric, Double-Asymme |
LED Chips | Samsung |
Suspension Cord | Including Suspension Cord Cost |
Wiring | Pre-Installation Wiring, Connect with Connector |
Transport Package | 10PCS/Carton |
Specification | 571*45*66mm |
Trademark | topenergys |
Origin | China |
HS Code | 94054090 |
Production Capacity | 5000PCS/Month |
Product Description
LED LINEAR TRUNKING SYSTEMThe LED Linear Trunking System is a continuous LED lighting system.All system components, trunking rail and luminaire inserts are perfectly matched according to 1500mm/600mm system dimensions.Triple, double and single-length rails can be combined to comply with the space involved.
FEATURES:
- Low installation cost - everything in one box and installation is tool-less
- The high light efficiency of 130 lm/W makes reduction on energy consumption and additional cost
- Ra >80
- CCT: 3,000K/4,000K/5,000K/6,000K
- Emergency versions available
- Dimming versions available
- Different length with various power is available
- X, L and T Standard Module Node connectors with electrical feed-in and feed-out
- Mounting Options: chain suspended, cord suspended, rod suspended or surface mounted
- Colour scheme: White
APPLICATIONS:
- Commercial
- Industrial
- Warehouse
- Other indoor lighting
Technical Data Sheet
Light Housing | |
Material | Aluminum profile |
Colour scheme | White |
Installation type | Rotatory knob or holding clamp |
Dimensions( Length x Breadth x Height) | 571 x 40 x 66mm |
Weight | Approx.4 kg |
Protection type | IP54 |
Illuminant properties | |
Illuminant Type | LED-Moduls with Mid-Power-LEDs |
Optical System | Wide,Narrow,wide,Flat and double Asymmetric light distribution |
Luminous Flux | 5200lm |
Luminous Output | 120lm/w -130lm/w (Customized) |
Colour Temperature | 3,000K / 4,000K / 5000K / 6000K |
Colour Rendering Index(Ra) | > 80 |
Dimming( Power control) | With / without DALI |
Lifetime at (ta)30° | 50,000 h |
Electronic Properties | |
Power Rating | 40W |
Protection class | SKI |
Operating voltage | 100 - 240V AC |
Frequency | 50 / 60 Hz |
Installation Requirements | |
Application areas | Halls,warehouses,manufacturing facilities,sales premises |
Specific Installation | Rail- Light System |
Installation height | 3 to 20m |
Permissible ambient temperature (ta) 30° | -25ºC to +35ºC |
Other properties | |
Certification | CE / TUV / SAA / UL |
Connection with circuit breaker (B16) | 150 Pcs |
Special features | |
End cover | IP20 |
Blind cover | |
Mounting Rail |
Node Connector
All system components can be combined without tools. X, T and L connectors expand the system's application range.
Each node connector has diverse of electrical feed-in and feed-out. The node connector is not only to connect the cross trunking,but also to connect the wire inside the trunking, and the node connector itself could even be the electricity feed-in point.
Illuminated modul
Connect with each other in series.
General safety instructions and information
Installation and maintenance must be performed by authorised and trained staff.
- Before wiring, make sure that the cables are de-energised. During wiring work, make sure that the cables remain
de-energised (e.g. prevent switching back on).
- Observe your national safety regulations for the installation and use of this lamp.
- The manufacturer accepts no liability for injuries or damage caused by unintended use or incorrect installation.
- If the lamp is retroactively modified, the person who made the modifications then becomes the manufacturer.
- To avoid risks, the lamp must only be operated if there are no visible signs of damage to components, in particular
to the connecting cable.
- Only the manufacturer is authorised to replace defective components.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similarly qualified person.
+ All dimensions stated in mm.
+ The drawings are not to scale.
+ Technical changes are reserved.
Connect with each other in series.
- General safety instructions and information
- Installation and maintenance must be performed by authorised and trained staff.
- - Before wiring, make sure that the cables are de-energised. During wiring work, make sure that the cables remain
- de-energised (e.g. prevent switching back on).
- - Observe your national safety regulations for the installation and use of this lamp.
- - The manufacturer accepts no liability for injuries or damage caused by unintended use or incorrect installation.
- - If the lamp is retroactively modified, the person who made the modifications then becomes the manufacturer.
- - To avoid risks, the lamp must only be operated if there are no visible signs of damage to components, in particular
- to the connecting cable.
- - Only the manufacturer is authorised to replace defective components.
- - The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
- similarly qualified person.
- + All dimensions stated in mm.
- + The drawings are not to scale.